Product Type SPA0*D & SPB0*D

IP RATING:
IP66 & Type 4X
OPERATING TEMPERATURE:
O-ring – None-100°C to +400°C
MATERIALS:
Brass, Stainless Steel or Aluminium
PLATING:
Electroless Nickel

Description

“SP” Series Certified Metallic Stopping (Blanking) Plugs provide a method of sealing unused entries in Ex equipment. They maintain Ex db, Ex eb and Ex ta methods of protection and IP66 for IEC type applications. They are Class I Division 1, Class II Division 1, Class II and Class 1 Zone 1 approved for NEC and CEC type applications whilst also maintain Type 4X rating.

Standards

COMPLIANCE STANDARDS:
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 60079-31 & 60529
C22.2 (see certificate), UL514B, UL1203, ANSI/UL 60079-0/1/7, ISA 60079-31, UL 50E

CERTIFICATION:
ATEX
I M2 II 1D 2G Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
UKEX
I M2 II 1D 2G Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
IECEx
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
CEC – Canada
Ex db IIC Gb / Ex eb IIC Gb / Ex ta IIIC Da
Class I Division 1, Groups A, B, C & D
Class II Division 1, Groups E, F & G
Class III, Type 4X
NEC – USA
Class I Zone 1 AEx db IIC Gb / AEx eb IIC Gb / Class II Zone 21 AEx ta IIIC Da
Class I Division 1, Groups A, B, C & D
Class II Division 1, Groups E, F & G
Class III, Type 4X
EAC – Russia
PB Ex db I Mb X / 1Ex db IIC Gb X / PB Ex eb I Mb / 1Ex eb IIC Gb X / Ex ta IIIC Da X
INMETRO – Brazil
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
CCC – China
Ex d I Mb / Ex d IIC Gb / Ex e I Mb / Ex e IIC Gb / Ex tD A20
UKRAINE
I M2 Ex db I Mb / Ex eb I Mb / II 2GD Ex db IIC Gb / Ex eb IIC Gb / Ex tb IIIC Db
CCoE – India
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb
ABS
Specified ABS Rules
LLOYD’S
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
DNV
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da

 

Certificates

CERTIFICATION No:
ATEX
CML 19ATEX1089X
UKEX
CML 21UKEX1039X
IECEx
IECEx CML 19.0022X
CSA – USA/Canada
CSA 2310046
EAC – Russia
RU-C-GB.АЖ58.B.05106-24
INMETRO – Brazil
NCC 13.2189 X
CCC – China
2021312313000377 – Chinese
2021312313000377 – English
ABS
20-LD1944057-PDA
LLOYD’S
LR2124442TA
DNV
TAE00004XK

 

Installation

Instructions – English
PA204 SPxx
Instructions – Portuguese
PA425 SPxx
Instructions – Russian
PA704 SPxx
Instructions – Chinese
PA804 SPxx

Drawings & CAD Models

ga_pcgatxspa
ga_pcgatxspb

CAD Models
Download here!

 

CONTACT

PEPPERS CABLE GLANDS LIMITED
STANHOPE ROAD,
CAMBERLEY,
SURREY,
GU15 3BT
UNITED KINGDOM

TEL +44 1276 64232

 

SOCIAL MEDIA

LEGALS