Product Type CR-S*F

IP RATING:
IP66 & IP68 (100 metres – 7 Days), Type 4X & DTS01:1991
OPERATING TEMP:
-60°C to +135°C
MATERIALS:
Brass or Stainless Steel
PLATING:
Electroless Nickel
COMPOUND:
Peppers T-1000 Sealing Compound

Description

“CR-S*F” type glands, used in any orientation, are certified Flameproof Ex db, Increased Safety Ex eb, Restricted Breathing Ex nR and Dust Protected Ex ta. They are suitable for use in Group I Mining, Zone 1 and 2 for Gas Groups IIA, IIB and IIC and additionally for use in Zones 20, 21 and 22 for Dust Groups IIIA, IIIB and IIIC. Also certified for Divison installations under CEC. Commonly referred to as a “Conduit Stopper Box”, they are suitable for use with conductors carried in conduit or as a line bushing for terminating flying leads. They provide a compound barrier Ex db & IP seal on the cable inner cores, eliminating damage to cables that exhibit “cold flow” characteristics. The unique features include Peppers T-1000, the sealing compound that enables a quick and easy installation and an innovative barrier chamber that allows for a full inspection of the compound fill. The gland maintains IP66 & IP68 to 100 metres and is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP O-ring seal as standard on metric entry threads. The gland is supplied with a female conduit connection thread.

Standards

COMPLIANCE STANDARDS:
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31,
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 60079-31 & IEC 60529
C22.2 (see certificate), CAN/CSA 60079-0/1/7, UL50

CERTIFICATION:
ATEX
I M2 II 1D 2G Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
II 3G Ex nR IIC Gc
UKEX
I M2 II 1D 2G Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex ta IIIC Da
II 3G Ex nR IIC Gc
IECEx
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da
CEC – Canada
Ex db IIC Gb / Ex eb IIC Gb / Ex ta IIIC Da
Class I Division 2, Groups A, B, C & D
Class II Groups E, F & G
Class III, Type 4X
EAC – Russia
PB Ex db I Mb X / 1Ex db IIC Gb X / PB Ex eb I Mb x / 1Ex eb IIC Gb X / 2Ex nR IIC Gc X / Ex ta IIIC Da X
INMETRO – Brazil
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da
CCC – China
Ex d I Mb / Ex d IIC Gb / Ex e I Mb / Ex e IIC Gb / Ex nR IIC Ga / Ex tD A20
UKRAINE
I M2 Ex db I Mb / II 2G Ex db IIC Gb / II 2G Ex eb I Mb / II 2G Ex eb IIC Gb
II 3G Ex nR IIC Gc / II 1D Ex ta IIIC Da
CCoE – India
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex nR IIC Gc
KCS – Korea
Ex d IIC / Ex e IIC
ABS
Specified ABS Rules
LLOYD’S
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da
DNV
Ex db I Mb / Ex db IIC Gb / Ex eb I Mb / Ex eb IIC Gb / Ex nR IIC Gc / Ex ta IIIC Da

 

Certificates

CERTIFICATION No:
ATEX
CML 19ATEX1344X
CML 19ATEX4114X
UKEX
CML 21UKEX1031X
CML 21UKEX4037X
IECEx
IECEx CML 19.0046X
CSA – Canada
CSA 1356011
EAC – Russia
RU-C-GB.АЖ58.B.05106-24
INMETRO – Brazil
NCC 13.2188 X
CCC – China
2021312313000422 – Chinese
2021312313000422 – English
UKRAINE
СЦ 18.0322 X
CCoE – India
PESO P494321/18 & P494321/20
KCS – Korea
15 GA4BO-0665X
15 GA4BO-0666X
ABS
20-LD1944057-PDA
LLOYD’S
LR2124442TA
DNV
TAE00004XK

Installation

Instructions – English
PA112 CR-Sxx
Instructions – Portuguese
PA412 CR-Sxx
Instructions – Russian
PA721 CR-Sxx
Instructions – Chinese
PA821 CR-Sxx

Drawings & CAD Models

ga_pcgatxcr-s

CAD Models
Download here!

 

CONTACT

PEPPERS CABLE GLANDS LIMITED
STANHOPE ROAD,
CAMBERLEY,
SURREY,
GU15 3BT
UNITED KINGDOM

TEL +44 1276 64232

 

SOCIAL MEDIA

LEGALS